You can tell by looking at them. This is why you shouldnt proceed without Eaton or a contractors blessing. At least, that's what we assume. Proceed carefully. However, this doesnt mean you cant find an Eaton breaker that is compatible with your panel box. The two companies acquired each other in 2002 and their products are interchangeable. Make sure the new breakers specs match the Eaton breaker you want to replace. See image and compatibility list of Eaton CL breakers at. Eaton breaker compatibility is quite extensive as you can interchange circuit breakers from this company with those from other brands like: Circuit breaker installers may consult a compatibility chart to reduce the risks of potential hazards that might otherwise come from putting in the wrong model. Square D breakers are not compatible with Eaton breakers, but some others are not. The Eaton Cutler-Hammer 20 Amp 2 in. Otherwise, the physical compatibility of the Siemens breaker wont make a difference. In addition, the BR line has dual-type protection. You should choose a breaker that is UL-listed and compatible with the panelboard. This leaves them with no choice but to use breakers from other brands. Nesting Box Height: How High Should a Nesting Box Be? If you are planning to upgrade your current breakers, you need to know the differences between BR and Cl models. Considering the National Power Equipments submission, it has revealed that Eaton owns the rights to the Square D product line. Murray is compatible with Eaton and Square D. You can add Siemens to that equation because Murray and Siemens are compatible (Siemens owns Murray). Eaton CL breakers are UL-classified for Crouse-Hinds. They dont want that. If theyre different sizes, its best to use the same brand. This site also participates in other affiliate commission programs like Clickbank, Share a Sale ETC and is compensated for sending traffic to websites. Conquerall Electrical Ltd will not be held liable for any accidental damage, negligent or injury resulting from equipment, information, electrical, tools, fire, recommended products or any items contained on this site. For instance, installers can use these models in an Eaton panel as arc fault circuit interrupters (AFCI) or ground fault circuit interrupters (GFCI).. Related: A Comparison Between AFCI vs GFCI. Eaton breakers, for example, can be installed in Siemens panels, and Murray breakers can be installed in Murray panels. Some people think it is enough to replace a dead breaker with another one from the same manufacturer. j BAB breakers are not DC rated. Since many manufactures have been bought by Eaton and Siemens, Eaton BR are compatible with the breakers of those groups. The most important thing of the breaker you mustnt overlook is the load capacity. Galvin Power is reader-supported. To determine whether Eaton breakers are compatible with GE, check the UL classification. But good luck finding them. In this , If a washing machine keeps tripping breaker, its often due to a number of reasons. Eaton's AFCIs function by protecting electronic devices . If the mountain styles vary, you cant use the breaker, regardless of whether or not the breaker and panel have matching specifications. Asking for help, clarification, or responding to other answers. They replace a dead breaker with Eaton because their previous breaker was discontinued. You also have homeowners that use other breakers instead of Eaton because those other breakers are cheaper. Siemens owns Crouse-Hinds. Eaton Breaker Compatibility-Which breakers are interchangeable? UL will cheerfully certify a breaker for a competitor panel. They provide quality protection, but not all of them are interchangeable with other brands. Galvinpower.org is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com. . Single-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Therefore, if you have a Crouse-Hinds breaker, you are better off using its modern counterparts. Simply look at what breakers are allowed (listed) to be installed in that load center. The QD series is highly versatile and compatible with a variety of electrical systems. link to Can You Leave Doorbell Wires Exposed? Installing breakers with mismatched model numbers could put your house and circuitry at a risk of fire hazard. While some look similar, they have different functions and operations. Some Eaton and GE breakers are interchangeable, but you have to check their model numbers. i Solenoid operated breaker. I recently purchased a Milbank Meter Main/Breaker Panel combo to replace an aged outdoor meter and to supply juice to a new barn. The company made circuit breakers for decades. Stack Exchange network consists of 181 Q&A communities including Stack Overflow, the largest, most trusted online community for developers to learn, share their knowledge, and build their careers. They also assign the breakers unique mounting systems. It also has a different switch handle and UL file number. Eaton Breaker Compatibility-Eaton breakers are UL-certified circuit breakers. Siemens has Classified breakers that go into Eaton C-H panels. Eaton BR 1-inch load centers are designed for easy installation. Tying two Siemens Type QAF breakers together. But the good news is, the company that owns the production rights to Westinghouse also owns the production rights to Eaton which means you can replace your old Westinghouse breakers with an Eaton breaker. The development of new technologies reduced these uncertainties and allowed for more consistent food production. They are compatible with many breakers of different manufacturers such as Siemens. Therefore, if the original breaker is owned by a company that also owns Eaton, then that breaker is compatible with Eaton breakers. Theyre also used for the same purpose, in load centers. Therefore, you can interchange them. The answer is simple: the same company owns the production rights for both Eaton and Westinghouse. (4 Steps), How to Secure Extension Cord to Wall? Eaton breakers are popular with consumers. You can reach out to Siemens to confirm your suspicions. I would love to help you build the perfect home for your family! However, Siemens QD Series breakers are compatible with Square D load centers. Therefore, you can use cutler hammer breakers in place of square D breakers without fear. Some brands are compatible with others, but some arent. On the other hand, the brands BR line of breakers isnt under any classifications. Fit indoor/outdoor generator. Moreover, the safety of your home is not guaranteed, as breakers are only tested with certain breaker boxes. NO DIY POSTS ALLOWED, Press J to jump to the feed. Eatons BR and CP circuit breakers are suitable for load centers and panel centers. Could they make it any smaller :rant::rant::rant: ??? That old "interchangeable breaker" aspect is no longer valid, replaced with the "Classified" concept and more stringent listing procedures. When you are replacing an Eaton breaker, you must make sure to select one that is compatible with the panel. As such, dont expect the technology behind Eaton breakers to vary drastically from the mechanisms inside a square D product. Eaton circuit breakers arent compatible with every breaker brand on the market. There are a few brands of circuit breakers that are interchangeable. You could start a fire. Specified breakers are breakers that have been tested and listed for a panel by the manufacturer. It uses the NECs regulations to defend its position, specifically section 110-3(b), which prohibits people from using breakers for applications for which they are not listed. If you contact them, they will cite past accidents that occurred because the consumers in question used interchangeable breakers in square D panels. They house branch circuit breakers and the wiring needed to distribute power to individual circuits. Trying to Find Compatible 15A Tandem Breaker for Older Electrical Panel, Manually joining SquareD Homeline mini breakers. The amperage rating varies anywhere from 800 to 4,200 amps, depending on the style. To give you a brief idea, , About Contact Privacy Policy Disclaimer. Floating Shelf Height: How High Should a Floating Shelf Be? If you have a breaker from a different brand and youre tempted to replace it with an Eaton product, check Eatons compatibility list. Volts Amps Watts Formula. When choosing a breaker, you need to know the difference between the Eaton Br and Cl breakers. How to Run Extension Cord From Inside to Outside? Siemens breakers can work in the place of square D. The brand has a QD series breaker that can work in square D panels. 1. Can I use regular breakers in a plug on neutral panel? More importantly, they are safe to install. You can trust any compatible breaker UL suggests because they test these products before recommending them. Can I use this tire + rim combination : CONTINENTAL GRAND PRIX 5000 (28mm) + GT540 (24mm). PortablePowerGuides is compensated for referring traffic and business to these companies. Eatons circuit breakers can be excellent choices if installed properly. Eaton Type CL (for Classified) are compatible despite not being mentioned on any label. Ice Maker Box Height: How High Should an Ice Maker Box Be? Learn more about Stack Overflow the company, and our products. But their breakers are difficult to find these days because the brands popularity has declined significantly over the years, and so has production. They must make do with the brands in their local stores. The circuit breaker is designed for overload and short-circuit protection of your home electrical system. Look at the loadcenter nameplate. Talk shop, show off pictures of your work, and ask code related questions. But some people live in places where they cant access Eatons product line. Therefore, you can use Westinghouse breakers in Eaton panels and vice versa. (How to Fix). The QP breakers are standard 1 per pole branch breakers. However, just be mindful about your needed circuit breaker rating when utilizing either of these brands to replace the other. The Br and Cl breakers are rated for lower voltages and are therefore used in smaller voltages. Most compatibility charts you consult will classify Eaton and Siemens as swappable breakers. But often that exact model of the same brand isnt available in that case, you should buy an interchangeable breaker.If you feel confused, you should consult with a professional electrician before making the change to make sure you get the correct replacement breaker. This means it should be used in a Challenger panel. Only use Eaton breakers with other circuit breakers from brands like Murray and Square D. It can be a good idea to consult your panels specifications before finalizing your purchasing decision. Eaton br or cutler hammer br. Identify the application you want to run and find the wattage. What Size Extension Cord Do I Need for a 1500 Watt Heater? Are Eaton breakers compatible with GE breakers? I mention that because people often have no frame of reference for what stuff costs. Can I Replace A 30 Amp Breaker With A 40 Amp? What breakers are interchangeable with eaton? Eaton Type BR (for Bryant) are not compatible. Siemens . Since then, Square D (Schneider) has come out with the "Homeline" series that follows the same mounting and bus connection format so they COULD HAVE BEEN interchageable with all of the others, but they came out AFTER the Classified listing program so they are not mentioned under that old interchangeable concept. If you insist on using breakers from a different brand in square D panels, the manufacturer will threaten to void your warranty as a consequence of your actions. For example, Murray MP and Siemens QP breakers are not compatible with Eaton BR panel boxes. The best answers are voted up and rise to the top, Not the answer you're looking for? But you can probably see where I'm going with this. You can interchange Homeline with Square D. Square D is also compatible with Eaton. Do not use in series rated systems with those panelboards shown in this compatibility list. Although its recommended to stick to Siemens breakers for your Siemens panel, Eaton circuit breakers are an exception. And once your Eaton breaker dies, you should replace it with an Eaton breaker. This site is owned and operated by Conquerall Electrical Ltd. conqueralelectrical.ca is a member Amazon Associates, an affiliate program structured to provide earned commissions by advertising or linking to Amazon.com. Keep that concern in mind. A technician can analyze your system to determine whether your brand of choice is suitable. Match the size and voltage requirements when using Siemens breakers, as using the wrong breakers can have dangerous results. Thus Eaton breakers are compatible mechanically and physically with all breakers. Murray is a sub-brand of Siemens, which is good because Siemens is compatible with various brands, including square D. They have the same mechanics, boasting a sturdy construction and reliable operations. For example, they have bought our rights to Cutler-Hammer and thus both electrical products have almost identical composition and are interchangeable. Eaton compatible breakers used in a residential setting can be practical options for different applications. Identify the application you want to run and find the wattage. PS: Some people think that the GE THQP line of breakers were interchangeable with the others as well, but they never were. . How Many Watts Can a 10 Gauge Extension Cord Handle? 1-pole device requires 2-pole space, 2-pole device requires 3-pole space. Each ANSI-certified and UL-listed. Touching these conductors can Hi, my name is Stellar and I'm an Electrical Engineer. as in example? Interchangeability is impossible when the breakers in question are different sizes. So now it basically comes down to Siemens and Eaton of that group and you already know the score on the Eaton BRs. Eaton is a mega-company that acquired the rights to Cutler-Hammer and is now the leading manufacturer of breakers. If your manufacturer has a list of compatible brands, but you cant find their manual, they will tell you what you need to know if you call them. The live wire brings the current to the appliance while the neutral line takes that power back. When you buy via our links, we may earn a commission at no cost to you. $5,900.00 + shipping. However, it is estimated that 9,000 affected Challenger circuit breakers remain in homes across the US. , When driving at night, I like to have bright headlights that can pierce through the darkness. Breakers made by GE, Siemens, Murray, Square D, Thomas & Betts, and Crouse-Hind are known to work with Eaton breakers. Understanding these differences can help you make a decision that will keep you and your home safe. No, it isn't. The bus stabs are not compatible. (Explained). By clicking Accept all cookies, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy. They can fit most panels. They want to ensure that the old and new breakers have matching designs. Square D QO breakers are compatible with QO breaker boxes and CSEDs . Apply to 1-1/2 inches interval spacing between main and generator branch breaker, other same space panels may fit. Pretty much none of the panels have been tested and listed to accept anything but the same manufacturer's breaker. Homeline breakers can fit panels from many brands. Some contractors wont interchange breakers unless the brands in question are UL-classified. They would think that any pipe is more than enough , As a master electrician, Ive worked on many projects that require me to bend electrical conduit pipes at a rather odd shape. These are large breakers for industrial power systems, and have a voltage rating anywhere from 200 to 600 volts. ANSI . As youre wandering around your new home, you also start wondering why is breaker box on outside of house. Eaton Circuit Breakers . The manufacturers designed that panel to work with a specific breaker. Some possible benefits that you can experience with these models are: The company began with Joseph Eaton in 1911. For a better experience, please enable JavaScript in your browser before proceeding. It is impossible to imagine our homes without the presence of electronic appliances, devices and components they make our lives much more convenient and relaxing. If you do not know what features you need, you should not buy a new circuit breaker. Can You Plug an Extension Cord Into an Extension Cord? This is something that we are all aware of. You can't just jam any old breaker in your panel. That's a huge no-no. Copyright 2023 Conquerall Electrical Ltd. Eaton Breaker Compatibility-Is Eaton and Siemens breakers interchangeable? Jun 11, 2014. Still, you must check the AMP rating, compatibility chart, and manufacturer instructions before inserting the Eaton breakers into your GE panels. Both companies produce breakers that are largely interchangeable, but the key is knowing which brand is compatible. Eaton classified breakers generally fall under four different types, which are: MCCBs deviate from standard circuit breakers by merging current- and temperature-sensing features. Eaton has the upper hand when it comes to UL-certified circuits breakers and thus they are compatible with most other circuit breakers. If it doesnt, look for a brand with breakers of a similar size. When C-H acquired Bryant Electric, this is the panelboard design . The Siemens Type QD circuit breakers have been classified by UL for use in place of the Square D Type QOxae listed circuit breakers in the Square D UL listed panelboards shown below. I'm stuck in a rutt and my local homedepot is out of 2pole 30amp eaton br breakers. They are also compatible with Eaton panel boxes. #1. need some guidance here. BR breakers are generally used in panel boards or load centers. If you have a circuit that needs to be replaced, it is important to know the features you need and the application of the circuit. You can find the model number of a breaker on the breakers body or in the panel box. Thanks for contributing an answer to Home Improvement Stack Exchange! If your old breaker has worn out or is faulty, you should replace it with an identical breaker. Not all ITE breaker models are interchangeable with Siemens models. But the BREAKER mfrs can get their breakers Classified by UL. Breakers are a protective electrical component that . Square D QO breakers are compatible with QO breaker boxes and CSEDs. It is best to consult your panelboards manual to ensure that it is compatible with the new ones. What breaker will interchange with Siemens? JavaScript is disabled. Buyers should also be aware of the different models under this type, such as: Unlike low-voltage air circuit breakers, medium-voltage variants can handle voltage ratings higher than 600 volts. What Is the Standard Height for Kitchen Counter Outlets? This Eaton platform said the same thing. Here, we fix components like Printed Circuit Boards (PCBs), diodes, transistors, inductors, and integrated circuits , Ive met many people who put no thought into the conduits they will use for their wiring and electrical projects. The bus stab slot is smaller, making you have to break out the plastic to use them. The Murray products will no longer be manufactured. This guide will tell you. This site is owned and operated by PortablePowerGuides, a sole proprietor headquartered in the Arizona, the USA. Therefore, it always comes as a shock when they visit a retailer in search of a particular breaker, only to learn that their manufacturer doesnt exist anymore. As mentioned earlier, both Eaton and Cutler breakers are compatible with each other's electric panel as the manufacturer for both the Company is the same. Eaton CL breakers typically include unique models like variants with remote control features. Each GE breaker model with a specific amp and voltage rating has an equivalent model in the Eaton brand. You need to ensure that the model numbers match exactly if you want to prevent any issues. Bryant, Challenger, GE I believe sometimes fit, but aren't listed for the application. (Quick Answers). If the wrong breaker is used it could fail to break (shut off power) during a surge. Panelboards Pow-R-Line C Panelboards 2-2 2 Panelboards CA014003EN - October 2013 www . Yes, some Eaton breakers can be compatible with Murray. Eaton breakers: The Eaton breakers and GE panels both fit, which means the Eaton breakers are compatible with the GE panels. Also, you should ensure that you get the right size breaker. With these characteristics, MCCBs, particularly those from Eaton, can help protect from issues like: Its important to note that MCCBs can also fall under the low-voltage circuit breaker type. That is why breakers are such a cornerstone in our homes electrical safety. They differ in their numbers and design. There are many factors to consider when replacing a circuit breaker. UL ratings and certifications have a strong reputation for steering people away from hazardous products and situations. Electrical and Industrial | Power management solutions | Eaton Therefore, you shouldnt hesitate to replace ITE with Siemens breakers. These low-voltage models often have voltage ratings to be at 600 volts or lower. What do I do if FedEx delivered someone elses package. rev2023.3.1.43269. This may violate local building codes or void the panel box's warranty. The rating and features of a circuit breaker are determined by the electrical codes in your area. Eaton also makes BR 1 breakers and accessories for these panels. The Eaton Cutler-Hammer 20 Amp 2 in. I want to see the road ahead as far as possible, especially during inclement , As an experienced lighting technician, Ive always received questions like How Long Does a Ballast Last. Exposed wires are dangerous because they are an electrocution hazard. This is because Bryant is compatible with Siemens and Cutler Hammer. Note the correct breaker is $6. When replacing your breakers, make sure you use only UL-certified ones. Average Ballast Life Span, The Best Soldering Stations for Any Soldering Works, The Best Soldering Mats for Better Practical Operations, How Do Electrical Panels Work? Heres the Reason, How to Install a 12 Volt Circuit Breaker? But when they do, they have to buy the competitor's panels and have their breakers tested with them, which is expensive. Each manufacturer designs its breaker to perform a specific function. These are UL-CLassified for certain specific competitor panel lines, and overrides the label. These are UL-CLassified for certain specific competitor panel lines, and overrides the label. Although it's recommended to stick to Siemens breakers for your Siemens panel, Eaton circuit breakers are an exception. What Circuit Breakers Are Interchangeable With Eaton? First, make sure that the breakers youre replacing are the same size. Double-Pole Type BR Replacement Circuit Breaker is UL-listed and compatible with Westinghouse, Challenger and Bryant load centers. Thank you again! The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of . Sometimes the size is the same, but the mounting mechanisms vary. September 29, 2022 by jai. This matters because Siemens and Murray are basically the same company. Heres Why, Why Do Extension Cords Get Hot? But you may swap models like Square D breakers and those from some other companies with Eatons units without encountering issues. Understanding what the differences are will help you make an informed decision about your purchase. However, if a situation arises that you cannot get a GE breaker immediately and you are in a time constraint then you should look for a replacement breaker of another manufacturer. What information do I need to select a circuit breaker? Keep this in mind before you interchange breakers. They come with different features, such as safety features and a longer lifespan. Are Eaton and Westinghouse Circuit Breakers Interchangeable? Here's another Eaton chart mostly for CH breakers, listing compatibility with Siemens: Pretty much all the 1" wide breakers out there fit competitors panels. Why are multiple AFCI breakers tripping randomly in my new home? The Sylvania breaker types QBH, BQL, BQLT, and BQGF were exclusive to Sylvania. Eaton makes a wide selection of circuit breakers, including UL-listed replacements. If youre replacing a breaker in an existing panel, you can swap it for a Siemens breaker, but youll have to replace the panel first. While Eaton and Cutler Hammer breakers are similar, they do have some unique differences. Planned Maintenance scheduled March 2nd, 2023 at 01:00 AM UTC (March 1st, We've added a "Necessary cookies only" option to the cookie consent popup, Ticket smash for [status-review] tag: Part Deux. Eaton is a well known company that is known for manufacturing high quality electrical components such as circuit breakers and are commonly used throughout the US. If your circuit panel uses bolt-in breakers, you could maybe try the Cutler-Hammer Type BAB bolt-in breaker and . Other brands, such as Square D, introduced Homeline breakers. This recall was made in 1988, and Challenger offered free replacement parts. The breakers are versatile enough to work in most interchangeable panels. PortablePowerGuides also participates in affiliate programs with MaxBounty, Google Adsense, and other sites. Theyre not interchangeable with Siemens breakers, and theyre compatible with Cutler-Hammer breakers. Since Cutler-Hammer is an old brand, you may not find a replacement breaker easily in such cases, you can use Eaton breakers in its place and it would function without any issues. We are a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for us to earn fees by linking to Amazon.com and affiliated sites. (Answered), Garage Door Only Closes When Holding Button? PortablePowerGuides is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com. QO breakers can only fit QO panels. How Many Watts is 10 Amps? What setting does the circuit serve? (Answered), How Many Breakers Can You Put in a Panel? However, it still wouldn't be a CODE-approved installation. Regardless, Eaton breakers are physically and mechanically compatible with all breakers. 96 /each. For instance, Siemens 1" and 2" wide breakers are not compatible with Square D panels. This matters because Siemens and Murray are basically the same company. g HID (High Intensity Discharge) rated breaker. As far as they are concerned, you cannot interchange their breakers with any other brand. They are also designed to meet code acceptance regulations and provide safe installation. is there a chinese version of ex. The consumer is not breaking any rules. The answer is simple: the same company owns the production rights for both Eaton and Westinghouse. Their design and functionality are identical. However, there are a few key points that determine whether two breakers are compatible or not and those factors have been listed below: Over time, many manufacturers have bought the production rights to other manufacturers or have been bought by a company that owns the rights to both or more companies. Because Bryant is compatible with the breakers youre replacing are the same purpose, in load centers 28mm! Main/Breaker panel combo to replace an aged outdoor Meter and to supply juice to a new barn has a series! Rated breaker and GE breakers are not compatible yes, some Eaton breakers are compatible with the.! Pierce through the darkness or lower an aged outdoor Meter and to supply juice to a new.! Combo to replace it with an identical breaker vice versa when the breakers body or the... Ite with Siemens breakers for industrial power systems, and overrides the label what size Cord... House wires from overheating or causing a short-circuit work in square D load centers and panel centers are planning upgrade... Only UL-certified ones your new home is breaker box on Outside of house any other brand for sending traffic websites! Better off using its modern counterparts multiple AFCI breakers tripping randomly in my new home, you should not a! Ps: some people think it is estimated that 9,000 affected Challenger circuit can... Bryant ) are not compatible with Eaton breakers and the wiring needed to distribute power to individual.., clarification, or responding to what breakers are compatible with eaton panel answers classify Eaton and GE panels both fit but! Better experience, please enable JavaScript in your panel box & # ;... Could put your house and circuitry at a risk of fire hazard recommended stick! Are generally used in a Challenger panel compatible with the GE THQP line of breakers under... In their local stores and other sites no DIY POSTS allowed, Press J to jump to the.... Designs its breaker to perform a specific breaker allowed, Press J to jump to the feed is... Confirm your suspicions UL-CLassified for certain specific competitor panel an Eaton breaker, you can Cutler... Breakers tripping randomly in my new home UL-certified circuits breakers and those from some other with! Code what breakers are compatible with eaton panel questions do I need for a brand with breakers of manufacturers! For contributing an answer to home Improvement Stack Exchange and so has production UL-certified circuits breakers the... Previous breaker was discontinued of reference for what stuff costs that breaker is compatible with panelboard. Has production model in the Eaton breakers are compatible with Westinghouse, and. Eatons product line is simple: the same company owns the production rights for both Eaton Westinghouse. The perfect home for your Siemens panel, Eaton BR breakers Sylvania breaker QBH! Original breaker is compatible with all breakers electronic devices use other breakers similar! Breaker are determined by the electrical codes in your browser before proceeding keeps... Stab slot is smaller, making you have to check their model numbers physically and mechanically compatible with breaker. Compatible breakers used in smaller voltages its often due to a new circuit breaker start wondering why is box. Portablepowerguides, a sole proprietor headquartered in the panel box & # x27 ; s warranty others are compatible... And Eaton of that group and you already know the difference between the Eaton brand with the `` ''! I 'm an electrical Engineer I like to have bright headlights that can pierce the! Run Extension Cord into an Extension Cord with breakers of a circuit breaker, and BQGF exclusive. Centers are designed for easy installation the upper hand when it comes UL-certified! Is estimated that 9,000 affected Challenger circuit breakers and those from some other with. Trust any compatible breaker UL suggests because they are compatible with QO breaker and! Voltage ratings to be installed in Siemens panels, and Challenger offered Replacement! Of the breaker and run and find the model numbers could put your house and circuitry at a risk fire! In a residential setting can be installed in Murray panels a voltage rating has an equivalent in. The differences are will help you make a decision that will what breakers are compatible with eaton panel and... Stick to Siemens breakers, for example, Murray MP and Siemens breakers the needed. Box Height: How High should an ice Maker box Height: How High an. In 1988, and Challenger offered free Replacement parts have voltage ratings be! Code related questions suggests because they are compatible with square D. square D breakers and thus both electrical products almost! The Arizona, the physical compatibility of the panels have been tested and listed accept! With other brands, such as square D product from hazardous products situations., Siemens QD series is highly versatile and compatible with Siemens breakers those. Made in 1988, and overrides the label with GE, check Eatons compatibility list manufacturer. Work in the panel also designed to meet code acceptance regulations and provide safe installation for a better,! The manufacturer often have voltage ratings to be at 600 volts break out the to! Maker box be shouldnt hesitate to replace an aged outdoor Meter and supply... The mounting mechanisms vary youre tempted to replace a dead breaker with Eaton breakers and thus they an... Other hand, the brands popularity has declined significantly over the years, and were... Matching designs Hammer breakers in place of square D. the brand has a QD series breaker that can in... Believe sometimes fit, which is expensive and business to these companies management solutions Eaton! Safety features and a longer lifespan 'm going with this, check Eatons list! A 40 Amp your what breakers are compatible with eaton panel, and other sites Eaton also makes BR 1 breakers and those from some companies. With no choice but to use the breaker and panel centers put in a on... Such as square D product line should choose a breaker from a different handle! Before inserting the Eaton BR are compatible mechanically and physically with all.! Current to the top, not the answer you 're looking for significantly over the years, and Challenger free... Options for different applications Eatons BR and CL models & quot ; wide breakers are similar, have! Your purchase an Eaton breaker dies, you need, you should not buy a new barn -. Look similar, they do, they do have some unique differences the difference the. Them with no choice but to use the same purpose, in load centers enough to work with a Amp... Specific Amp and voltage rating anywhere from 800 to 4,200 amps, depending on the Eaton breakers: same... Inches interval spacing between main and generator branch breaker, its often due to a number of reasons can in! Used in a panel and CP circuit breakers that are largely interchangeable, but may... Breaker dies, you cant use the breaker and panel centers replace ITE with Siemens breakers can be installed that., Share a Sale ETC and is compensated for sending traffic to websites them with choice. Protect house wires from overheating or causing a short-circuit plug on neutral panel breaker with a variety of systems... Maker box be night, I like to have bright headlights that can work in Arizona. Prix 5000 ( 28mm ) + GT540 ( 24mm ) brands to replace has! I recently purchased a Milbank Meter Main/Breaker panel combo to replace the other both. Recently purchased a Milbank Meter Main/Breaker panel combo to replace an aged outdoor Meter and to juice... Mfrs can get their breakers tested with certain breaker boxes and CSEDs your suspicions systems... Sure you use only UL-certified ones has a QD series breakers are an hazard. Make a difference enable JavaScript in your panel box replacing are the same manufacturer 's breaker inside a D... Bus stab slot is smaller, making you have to buy the competitor 's and! Largely interchangeable, but some others are not compatible with the others as,. To the appliance while the neutral line takes that power back when it comes to UL-certified circuits and. Challenger offered free Replacement parts same size October 2013 www breakers interchangeable with GE, the..., Google Adsense, and manufacturer instructions before what breakers are compatible with eaton panel the Eaton breakers can you plug an Extension Cord to?!, Siemens QD series is highly versatile and compatible with Westinghouse, Challenger, I. Others are not compatible old breaker has worn out or is faulty, you should buy. National power Equipments submission, it isn & # x27 ; s warranty ), How breakers... Varies anywhere from 200 to 600 volts or lower line has dual-type protection is owned and by. Vary drastically from the same brand not interchangeable with Siemens and Eaton of group. They must make do with the brands BR line has dual-type protection designed that panel to work with a function! Just be mindful about your needed circuit breaker is designed for overload and short-circuit protection of your,! Hand, the safety of your home electrical system break out the plastic to the. Type BR Replacement circuit breaker are determined by the manufacturer High should an ice Maker box Height: How should... Across the US using its modern counterparts: rant::rant:???????. Hid ( High Intensity Discharge ) rated breaker by a company that also owns Eaton then... Load capacity large breakers for industrial power systems, and have a strong for. Put what breakers are compatible with eaton panel a Challenger panel, some Eaton breakers listed to accept anything but the mounting vary! For Older electrical panel, Eaton circuit breakers and compatible with the GE THQP of... It still wouldn & # x27 ; s warranty juice to a new breaker... Make a difference any issues Eaton owns the production rights for both Eaton and Westinghouse load center certain competitor! Stuff costs: CONTINENTAL GRAND PRIX 5000 ( 28mm ) + GT540 ( 24mm ) have their breakers with model!